AC-PLAZMAX

  • Brand: Tuttnauer
  • Reference: AC-PLAZMAX

   

Share

Plasma Low Temperature Sterilization

with Vaporized Hydrogen Peroxide

For heat and moisture sensitive equipment

PlazMax provides an efficient sterilization solution for heat & moisture sensitive equipment in CSSDs and Gastroenterology & Respiratory Endoscopy Clinics.

PlazMax will give you the lowest rate of failed cycles than any other hydrogen peroxide plasma sterilizer on the market. You get increased productivity, reduced risk of work stoppage, and efficient supply of sterilized equipment where it’s needed.

In operating rooms PlazMax benefits you with almost immediate access to sterilized equipment. Simple to install and control, only requiring 1-phase electricity and Hydrogen Peroxide (H2O2) packs to operate. No need to send equipment to a CSSD, eliminating the risk of damage and contamination in transit.


 

ADVANCED AND FLEXIBLE CONTROL SYSTEM

Take Advantage of Tuttnauer’s state-of-the-art control system with multicolor touch screen display. Includes equipment tracking and maintenance notification features.

25 MINUTES FAST AND PRODUCTIVE

PlazMax cycle times are as low as 25 minutes (P50 normal cycle).


WIDE RANGE OF CHAMBERS

Don’t over pay for two small sterilizers when you can buy one large sterilizer. Choose from 3 models with chamber sizes from 47 to 109 liters.

KEEP RUNNING COSTS LOW

Keep you consumable costs low
With PlazMax you have the freedom to use commonly available market accessories such as indicators, pouches & rolls, etc. that are suitable for sterilization with vaporized hydrogen peroxide. Tuttnauer also sells sterilant, and biological & chemical indicators.

CLEAN TECHNOLOGY

  • Non-toxic sterilizing agent
  • Minimal utility requirements – low electricity consumption, no water consumption
  • The sterilization process results in water and oxygen by-products


VERTICAL SLIDING DOOR

Automatic Vertical Sliding Door with built-in foot operated device for hands-free door operation.


 

TOUGH CHALLENGES – PCD

By challenging the PlazMax sterilizer with our Process Challenge Device (optional) you will be confident that it does its job at the highest sterilization levels.


 

SAFETY FEATURES

Tuttnauer strives to provide sterilizers hat ensure safety for patients, staff, and the environment. Safety features include:

  • No hazardous or odorous emissions
  • Low temperature and low pressure during sterilization
  • Door is locked during cycle operation

Technical Specifications

Model Volume
(Liter)
Chamber Dimensions (WxHxD) mm External Dimensions (WxHxD/D 2-doors) mm No. of Baskets 40x60 (WxD) cm

Power (W) Current (A)

Voltage V
1-Phase
50-60 Hz

P50
47
420 x 180 x 624 702 x 1528 x 729 / 736
1
3100 W
13.5 A
230 V
P80
83
420 x 320 x 624 702 x1668 x729 / 736
2
3400 W
14.7 A
230 V
P110
109
420 x 420 x 624 702 x 1768 x729 / 736
2
4300 W
18.7 A
230 V
 


Advanced Control System for Your CSSD

Take advantage of Tuttnauer’s sophisticated user-friendly control system for repeatable high performance with Tuttnauer’s sophisticated Bacsoft controller.

Standard Features

  • 7” Multi-color touch screen panel (also on second door of two door configurations)
  • Stores the last 200 cycles in built-in memory
  • Multiple access levels and user passwords to control access/operation of the PlazMax
  • Diagnostic In/Out test (enables technician to check each system component separately)
  • Sterilization Temperature range 50°C to 55°C
  • Thermal printer
  • USB and Ethernet connection port

Sophisticated Touch Screen HMI

The HMI (Human Machine Interface) has been designed with the following considerations:

  • Multi-color display for easier reading from a distance
  • Multilingual (26 languages)
  • Dynamic graph displaying the chamber pressure and the cycle process
  • Displays process info – pressure, temperature, vaporizer temperature.


Equipment Tracking & Maintenance Notification

Equipment tracking software provides a detailed sterilization history of each endoscope tracked using barcodes. The software will notify the user when equipment needs to be returned back to the original equipment manufacturer for maintenance.


Sterilization Cycle and Test Programs

 

Model
Normal Cycle
(Non-hollow loads)
Advanced 
Cycle (Hollow Louds)
Endoscope * 
  Cycle Time (min.) Cycle Time (min.) Cycle Time (min.)
P50 35 40 28
P80 35 40 28
P110 45 50 30

* Endoscope cycle temperature: short heating time and reduced H2Oexposure time
Note: Cycle times are based on a hot cycle and may vary according to load volume.

Non-Hollow Loads

Non-hollow loads are sterilized with the “Normal Cycle”.










































Hollow Loads

Hollow loads are sterilized with the “Advanced Cycle”.


 


Endoscopes

Endoscopes and similar equipment are sterilized with the “Endoscope Cycle”.

• The instruments and equipment presented are only a partial list of the wide range that can be safely sterilized in PlazMax
• Only use PlazMax with equipment authorized by original manufacturer to be sterilized with plasma sterilizers.

R.PC.R Software

Automatic recording of cycle information to any PC on your
network

 

Reporting You Can Rely On

  • Convenient access to graphs and tables that are easy to understand
  • Easily generate PDF reports
  • No need to file printouts, saving you time

Be in Control with Real-Time Remote Monitoring

  • See the real-time autoclave display on your PC
  • Monitor all activity for up to 8 sterilizers

With R.PC.R you can see: Graphs of the cycle data, Numeric cycle
data, cycle print-outs, measured values table, parameter table.

'
 

Software and Hardware



USB Digital Cycle Data

Connect a USB memory device to the PlazMax and you can
download a soft copy of cycle printouts and all cycle data history
stored in the sterilizer’s memory.