PlazMax provides an efficient sterilization solution for heat & moisture sensitive equipment in CSSDs and Gastroenterology & Respiratory Endoscopy Clinics.
PlazMax will give you the lowest rate of failed cycles than any other hydrogen peroxide plasma sterilizer on the market. You get increased productivity, reduced risk of work stoppage, and efficient supply of sterilized equipment where it’s needed.
In operating rooms PlazMax benefits you with almost immediate access to sterilized equipment. Simple to install and control, only requiring 1-phase electricity and Hydrogen Peroxide (H2O2) packs to operate. No need to send equipment to a CSSD, eliminating the risk of damage and contamination in transit.
Take Advantage of Tuttnauer’s state-of-the-art control system with multicolor touch screen display. Includes equipment tracking and maintenance notification features.
PlazMax cycle times are as low as 25 minutes (P50 normal cycle).
Don’t over pay for two small sterilizers when you can buy one large sterilizer. Choose from 3 models with chamber sizes from 47 to 109 liters.
Keep you consumable costs lowWith PlazMax you have the freedom to use commonly available market accessories such as indicators, pouches & rolls, etc. that are suitable for sterilization with vaporized hydrogen peroxide. Tuttnauer also sells sterilant, and biological & chemical indicators.
Automatic Vertical Sliding Door with built-in foot operated device for hands-free door operation.
By challenging the PlazMax sterilizer with our Process Challenge Device (optional) you will be confident that it does its job at the highest sterilization levels.
Tuttnauer strives to provide sterilizers hat ensure safety for patients, staff, and the environment. Safety features include:
Power (W) Current (A)
Voltage V1-Phase50-60 Hz
Take advantage of Tuttnauer’s sophisticated user-friendly control system for repeatable high performance with Tuttnauer’s sophisticated Bacsoft controller.
The HMI (Human Machine Interface) has been designed with the following considerations:
Equipment tracking software provides a detailed sterilization history of each endoscope tracked using barcodes. The software will notify the user when equipment needs to be returned back to the original equipment manufacturer for maintenance.
* Endoscope cycle temperature: short heating time and reduced H2O2 exposure timeNote: Cycle times are based on a hot cycle and may vary according to load volume.
Non-hollow loads are sterilized with the “Normal Cycle”.
Hollow loads are sterilized with the “Advanced Cycle”.
Endoscopes and similar equipment are sterilized with the “Endoscope Cycle”.
With R.PC.R you can see: Graphs of the cycle data, Numeric cycledata, cycle print-outs, measured values table, parameter table.'
Connect a USB memory device to the PlazMax and you candownload a soft copy of cycle printouts and all cycle data historystored in the sterilizer’s memory.