產品詳細說明


  下個產品  大型消毒爐

大型消毒爐


[產品編號: AC-T-MAX-NARROW]



大型消毒爐





數量:  


Autoclave for CSSD sterilization - T-Max - Tuttnauer

 

The autoclave operates with saturated steam as the sterilizing agent with a temperature range of 105 °C (221°F) to 138 °C (280 °F) and a working pressure that meets AMSE and PED requirements. The T-Max autoclave model is available with either single or double vertical sliding door


ENGINEERED WITH PEOPLE IN MIND

 

Our quality features enable the convenience and durability needed to operate a sterilizer with complete peace of mind.

The chamber is constructed of long lasting 316L grade stainless steel with superior corrosion resistance. The chamber is fully jacketed for uniform heat distribution. In addition, the generator and piping are constructed of stainless steel. The pneumatic valves are air pressure operated, significantly reducing maintenance.

To save energy, the sterilizers automatically switch to a standby mode.

SAFETY IS OUR TOP PRIORITY

Door Safety

The autoclave doors are designed with a number of independent mechanical and digital safety features.

  • A safety device prevents the operator from opening the door when chamber is pressurized
  • Steam will not to enter the chamber when the door is open
  • A cycle cannot start if the door is open or not properly locked
  • The door cannot unlock until chamber pressure reaches room pressure
  • Sliding Door Safety - sliding door progress will automatically stop if an obstruction is detected
  • Double Door Safety – interlocks prevent both doors from being opened simultaneously

General Safety Features:

  • Double Independent Monitoring: The combined electronic and mechanical monitoring ensures that the operator has two independent means to monitor pressure
  • Safety Valves: If the pressure exceeds the allowed limit the safety valves will discharge
  • Built-in Steam Generator Safety: A water level monitoring system maintains a constant water level and ensures safe operation of the heaters
  • Emergency shut-off: Easily accessible emergency switches for immediate cycle shut-off
Model
Chamber Volume (Liter) StU Capcity Chamber Dimensions
(WxHxD) mm (inc.)
T-Max 2
175 Liter
2
360 x 710 x 705
T-Max 4
310 Liter
4
660 x 660 x 710
T-Max 6
430 Liter
6
660 x 660 x 990
T-Max 8
565 Liter
8
660 x 660 x 1295
T-Max 10
700 Liter
10
660 x 660 x 1620

 

Advanced Control System for Your CSSD

Take advantage of Tuttnauer’s sophisticated user-friendly control systems for repeatable high performance. Choose either Tuttnauer’s sophisticated Bacsoft controller or the Allen-Bradley (AB 1400 PLC) controller.

Standard Features

  • 7” Multi-color touch screen panel
  • Keypad control panel on second door of two door autoclaves with Bacsoft controller
  • Stores the last 200 cycles in built-in memory
  • Multiple access levels and user passwords to control access/ operation of the autoclave
  • Diagnostic In/Out test (enables technician to check each system component separately)
  • Sterilization Temperature range 105°C to 138°C

Optional Features

  • 10” Multi-color touch screen
  • 21 CFR part 11
  • Up to 8 different barcode readers
  • Independent Recording for cross-checking cycle measurements
  • Disinfection/Isothermal Temperature range from 70°C to 95°C

Sophisticated Touch Screen HMI

The HMI (Human Machine Interface) has been designed with the following considerations:

  • Multi-color display for easier reading from a distance
  • A Color wheel is used to indicate the stage of the cycle
  • Multilingual (26 languages)

 

 

 

 


 

Process documentation is crucial within the CSSD. The modularity and flexibility of our system gives you targeted and customized solutions to track and document the sterilization process.

The modularity and flexibility of our system gives you targeted and customized solutions to further improve the tracking and documentation of the sterilization process. The following documentation features are optional.

Validation Packages

Tuttnauer provides our customers with services to help expedite the validation and commissioning of your equipment, including:

  • Factory Acceptance Testing (FAT)
  • Site Acceptance Testing (SAT)

Barcode Reader

The barcode reader allows material identification. The data is transferred to the SCADA software and linked to the sterilization cycle parameters for streamlined instrument handling.

Independent Chart Recorder

The Chart Recorder is an independent temperature and pressure measuring system. It gives clear analog/mechanical trend records and print-outs in color. It is simple to operate and has an easy-view display.

Backup of Cycle History Data

A record of cycle history data is critical for hospitals that need reliable documentation. The cycle history backup system stores thousands of hours of cycle data, displayed either graphically or numerically.


ENGINEERED WITH PEOPLE IN MIND

 

Our quality features enable the convenience and durability needed to operate a sterilizer with complete peace of mind.

The chamber is constructed of long lasting 316L grade stainless steel with superior corrosion resistance. The chamber is fully jacketed for uniform heat distribution. In addition, the generator and piping are constructed of stainless steel. The pneumatic valves are air pressure operated, significantly reducing maintenance.

To save energy, the sterilizers automatically switch to a standby mode.




 
最新消息
有關Biobase醫療冰箱安全警示之聲明   [2017-10-20]
我們已發公告函給我們所有受影響的客戶。 就此次事件我們盡力的盡我們代理商的本份。發現問題後亦即時上報給生產商。盡我們的能力說服生產商並確認問題, 盡力避免危及大眾健康的意外發生。有問題 , 總在疫苗來之前發現,比起疫苗來之後為好。 收到生產商的指引後我們亦盡快收集所有的資料,並上報於客戶及衛生署。現時正積極地尋求解決方案,盡可能配合衛生署及疫苗計劃,去應付客戶將面對疫苗儲存的燃眉之急。 對於這個問題造成的任何不便,我們深表歉意。 2017年10月20日(星期五)香港時間22時50分 衛生署發出新聞稿,詳情可請見以下網頁。 http://www.info.gov.hk/gia/general/201710/20/P2017102001060.htm


 